What is ATTIVA Radiofrequency Treatment?
What is ATTIVA radiofrequency treatment? What is Attiva S.I.H. technology? S.I.H. is short for subdermal-induced heat technology and describes the ability to administer thermal energy to soft tissue cells and collagen fibers with localized heat application. The heat is applied with sleek wands administered without the need for an incision. ATTIVA is an Italian medical health company that has developed S.I.H. This novel technology provides the opportunity to deliver controlled thermal energy that effectively shrinks collagen molecules along the undersurface of the skin and throughout the soft tissues spanning throughout the skin, soft tissues, and even the muscle fascia. The beneficial effects of S.I.H. are observed in an immediate, subacute, and delayed fashion.
The immediate benefit of heat induction is to contract the collagen molecules that are located on the undersurface of the skin, i.e. the dermis, throughout the soft tissues, i.e. fibro-septal network, and even the fascial layers located in the deeper soft tissues and overlying muscle bundles. The subacute phenomenon of heat exposure is the vasodilation of vascular cells. A final delayed benefit of S.I.H. is the stimulation of biological cells that include fibroblasts and myofibroblasts resulting in a prolonged increase in collagen and elastin production. The net effect of S.I.H. technology is a safe solution to treating signs of aging without surgery. In summary, S.I.H. technology offers aesthetic enhancements to the quality of your skin and soft tissues with minimal downtime, avoidance of scarring, and long-lasting results.
Aging results in the reduction of both collagen and elastin, the recoil protein that exist within the skin. As the elastin protein density diminishes, the skin loses its ability to recoil, best characterized by a rubber band. As a rubber band ages, it becomes brittle and loses its ability to snap back. The loss in the recoil effect of elastin is most appreciated following significant weight loss. When you lose significant weight in your 20’s, the skin will snap back since elastin in plenty. However, after age 40 to 45, significant weight loss results in skin sagging and unappealing skin wrinkling and irregularities.
The aging effect is further compounded by gravity that acts like a continuous weight that tugs on the skin and soft tissues. Decades of continued tugging naturally result in the stretching out of the skin. When gravity is combined with loss in elastin, the skin sagging becomes expounded! The above detrimental effects are typically countered by structurally stabilizing collagen fibers located along the undersurface of the skin and spanning throughout the soft tissues. When collagen production slows down with aging, then the skin and soft tissues become further compromised.
The final detrimental effect on the skin is sun radiation, which results in the bombardment of skin cells by the damaging radiation waves of the sun. The net effect of radiation damage is a malfunction of protein expression of DNA by poorly performing cells, called epigenetics; increasing skin cell expression of beneficial proteins, such as collagen and elastin, will counter premature aging that results in loss of turgor and sheen.
Benefits of ATTIVA Radiofrequency Treatment
ATTIVA® Subdermal Induced Heat (S.I.H.) Technology is the result of 5 years of advanced scientific research. Three international patents protect ATTIVA subdermal-induced heat technology. This technology may be employed by medical professionals such as physicians, naturopathic doctors, nurse practitioners, physician assistants, and registered nurses. This range of medical providers who may treat the signs of aging, prolonged gravity, and sun damage without invasive surgery translates to efficient, safe, and affordable treatments.
ATTIVA® S.I.H. Technology offers patients dramatic aesthetic enhancements to the quality of their skin and soft tissues with minimal downtime, no scarring, and immediate results. A new benchmark in the medical treatment of aging, sun damage, and loose skin without the need for general anesthesia and prolonged recovery is now available. ATTIVA subdermal induced heat S.I.H. technology provides several real advantages not offered by any other medical device alternatives that include:
- Minimally invasive treatment that can be completed in the office while you remain awake
- Avoidance of incisions that can result in subsequent scars
- Precludes the need for infiltration of fluids and/or gasses prior to treatment
- Immediate improvements following a “lunchtime” procedure
- A quick recovery period means no income loss or setbacks in your social calendar
- Reducing mechanical trauma resulting in unnecessary soft tissue injury or swelling
- Minimizing the risk of skin compromise with external skin monitoring and temperature safety gauges
- Less inconvenience associated with frequent postoperative visits to the clinic
How does ATTIVA technology work?
Subdermal-induced heat technology describes a minimally invasive procedure that improves skin laxity and appearance previously achieved only by surgery. The beneficial effects of ATTIVA are multi-fold. The first occurs immediately following a contraction of collagen molecules in both the soft tissues and the deep layer of the skin, called the dermis. The shrinking of collagen molecules exposed to heat is coined subdermal coagulation and is permanent, best appreciated by the analogy of grilling a steak. Grilling a steak results in immediate shrinkage as the collagen molecules become denatured. Denaturing collagen proteins occurs by breaking intramolecular bonds, resulting in a contracture of its helical configuration that converts to shorter and thicker helixes.
The next benefit of ATTIVA is subacute and involves vasodilatory expansion of capillary and arteriolar microcirculation directly resulting in hyper-oxygenation and removal of pro-inflammatory products thereby expediting tissue regeneration. The final benefit of ATTIVA is delayed and involves its biological effects at a cellular level. The heat exposure of fibroblasts and myofibroblasts results in increased collagen and elastin production respectively. Specifically, the proteo-synthetic effects of ATTIVA have been shown to increase the production of type I and type III collagen. The increase in collagen production has led to an increase in dermis consistency and density, which can be appreciated both visually and by feeling best described by a reduction in skin elasticity.
ATTIVA® is a Radiofrequency (R.F.) System approved in the United States ATTIVA® Radiofrequency (R.F.) System (generator, electrodes/handpieces, and accessories) for treating skin and soft tissues. Radiofrequency emits electromagnetic waves, leading to a rise in the internal temperature of tissues involved in treating electrocoagulation and hemostasis termed subdermal coagulation. The rise in internal temperature has additionally fostered collagen contraction, and vasodilation with the beneficial consequence of the increase in cell oxygenation, as well as bio-stimulation of cellular components. ATTIVA® device should be used on adult patients only.
ATTIVA Mechanism of Action
ATTIVA is a special radio frequency device that transfers controlled a unique combination of radiofrequency waves through a sleek probe that is introduced through imperceptible ports created without the need for an incision. The applied radiofrequency waves have proved effective in the structural and functional restoration of the collagenous matrix for the following reasons.
- ATTIVA utilizes proprietary wavelengths in the radiofrequency designed to obtain maximum interaction with the treated tissues. In fact, the heat produced by the energy, maintained below 60 ° C, is safely transferred to the tissues causing an electrical stimulation on the fibroblast cells.
- The mechanical effect of the probe, applied subcutaneously, produces a specific stimulus on the fibroblast cells that supplements the electrical-thermal stimulation described above.
- Direct action on the stem cells of the treated structure, so that in addition to the fibroblasts already mentioned, the radiofrequency wavelength produces both thermal vasodilation and regeneration of arterial-veno-lymphatic capillaries, resulting in optimized delivery of nutrients and removal of catabolites of all soft tissue cells.
- The deconstruction and reconstruction of the fibrillar fascia and its functional restoration through the regeneration and neo-production of proteins, such as collagen and elastin.
Beneficial effects observed above are made possible by the precise and safe delivery of energy which in turn translates into a controlled heat of up to half a degree through each pass. The subjective effectiveness of the results is supported by histological studies in which no secondary fibrosis has been detected.
Development of collagenous matrix without fibrosis
ATTIVA Radiofrequency Treatment Recovery
What makes ATTIVA Radiofrequency S.I.H. recovery unique is its seamless transition from treatment to full recovery. Since patients avoid general anesthesia patients may drive to the office or utilize ride-sharing companies such as Uber to and from their procedure. Since patients avoid surgical interventions such as incisions or infiltration of fluids such as tumescent solution or gases used by alternative skin and soft tissue tightening machines, typical procedure side effects are avoided. Recovery advantages include negligible discomfort in the procedure area, only transient redness, and minimal swelling. Instead, improvements in the appearance of and reduction in skin looseness are immediately appreciated.
Clients today demand efficient and safe procedures from their physicians to improve the quality of their skin quality and body contour. The realization that topical treatments are often not adequate to solve their skin problems, coupled with their fear of surgery, leads many to opt for a non-surgical, minimally invasive technology such as ATTIVA. ATTIVA® S.I.H. Technology achieves long-lasting results with minimal downtime and no scars.
The first reason for ATTIVA’s expedited recovery is the ability to avoid surgical incisions. Instead, small pokes created with an Awl or needle stabs are utilized to create imperceptible ports for the introduction of the treatment wands.
Furthermore, the safety of ATTIVA S.I.H. technology stems from its unique technology and protocol. The use of a thermal-camera in real time allows for double temperature control. Specifically, the temperature of the probe tip where radiofrequency energy is administered is confirmed; temperatures of 42 to 50 degrees Celsius are integral to obtaining collagen contraction and bio-stimulation of soft tissue cells. Additionally, the temperature of the external skin is monitored so that a harmful temperature of 42 degrees Celsius is avoided at all times. Patented technology self-monitors and automatically lowers energy fluences when preset maximum internal temperatures are reached.
ATTIVA Radiofrequency Treatment Safety
Both male and female clients today demand effective, safe, and minimally invasive alternatives to improving their appearance. Our clients are keen on researching various radiofrequency options searching for the best treatment solutions. Most clients realize that not all Radio Frequency (R.F.) technologies are identical. They understand the importance of the safety of a temperature-controlled procedure to ensure the integrity of their skin. Thanks to the high precision of the ATTIVA® treatment, medical providers can obtain the best results in skin tightening and body contouring without scars and with minimal downtime. The subdermal-induced heat technology has proven to be extremely efficient and safe. A built-in Double Temperature Control ensures the safety of subdermal-induced heat technology on the device.
This feature, combined with an external thermo-controlled camera, allows constant monitoring of the probe inside the tissues and of the superficial skin temperature. The highly sensitive thermal imaging camera allows for accurate control of skin temperatures.
During the entire session, the physician monitors the parameters and the results.
To ensure the patient’s safety, ATTIVA® RF has a built-in double temperature control on the cannula. This technology, combined with an external thermos-controlled camera, allows constant monitoring of the probe inside the tissues and the superficial skin temperature.
ATTIVA® S.I.H. Technology delivers optimal results through minimally invasive facial lifting, body contouring, and skin tightening procedures. The double real-time temperature control and the high precision of the thermocouple provide an unequaled safety level during the entire procedure with a complete focus on the treated area. The proprietary software and patented subdermal-induced heat technology allow your medical provider precise control of the thermal diffusion from the deep tissues up to the skin’s surface. Patented ATTIVA capacitive transducers work with tensions up to 10 times lower than any.
ATTIVA Radiofrequency Treatment – Reduced Skin Elasticity
The old technology of radiofrequency lifting consisted of heating the skin’s surface long enough for the subcutaneous tissue to heat up to 42 ° Celsius for over 1 minute or up to 82 degrees for a fraction of a second. The limitations of these procedures were the excessive heating of the skin surface and the possibility of burns. With the new ATTIVA subdermal-induced heat technology, signs of skin aging are effectively and safely reversed without prolonged recovery periods and the risk of scarring. The advantage of ATTIVA thermal heating of collagen fibers is that therapeutic internal temperatures are safely controlled until desired resulting in in immediate collagen contraction as well as delayed production of collagen fibers resulting in active retraction of skin against the underlying muscle fascia.
ATTIVA Radiofrequency Treatment – skin lifting
What does ATTIVA radiofrequency lifting look like? The procedure is painless because the anesthetic is given via injection to the site with a flexible microcannula. A thin electrode is then applied to the anesthetized skin, emitting radiofrequency and moving carefully through the skin, soft tissues, and even the underlying muscle fascia depending on the depth of treatment and desired region.
The entire treatment is controlled by a camera that measures the temperature of the skin surface and internal therapeutic temperatures in a completely safe fashion. After the treatment, the skin’s appearance is unchanged. Occasionally, transient bruising or mild swelling may develop after treatment. The lifting effect is twofold; the immediate effect results from the contraction of soft tissue collagen fibers and muscle fascial planes. Additional lifting becomes visible after 4 to 6 weeks and more pronounced over time due to new collagen production. Further lifting results may be achieved with additional treatments that can be repeated after several years.
ATTIVA Radiofrequency Treatment – Improvement in skin appearance
Immediately after the first session, most patients will see improvements that continue to improve with full results in 2 to 3 months following the treatment. The reason for continued improvements is the bio-stimulation that the radiofrequency energy conveys to produce new elastin and collagen fibers. The optimal results are achieved by 3 to 6 months as observed by histological samples and will be appreciated long-term for several years.
ATTIVA Radiofrequency Treatment – Frequently Asked Questions
Am I a good candidate for ATTIVA?
ATTIVA S.I.H. is suitable for those who want to tighten the skin and smooth out wrinkles in a single session without the downtime and the risk associated with surgery.
Is ATTIVA Radiofrequency treatment safe?
The subdermal-induced heat technology has proven to be extremely efficient and safe. A built-in Double Temperature Control ensures the safety of the device. Combined with an external thermos-controlled camera, this control allows constant monitoring of the probe inside the tissues and the superficial skin temperature. During the entire session, the physician monitors the parameters and the results.
How long does it take to see visible results?
Immediately after the first session, most patients will see improvements and appreciate full results in 2 to 3 months following the treatment. The reason for continued improvements is the biostimulation that the radiofrequency energy conveys to produce new elastin and collagen fibers.
How long will the result last?
The optimal ATTIVA radiofrequency treatment result is achieved after 3 to 5 months and will be appreciated long-term for several years.
Is ATTIVA subdermal-induced heat treatment painful?
The ATTIVA radiofrequency treatment procedure is painless; the treated area requires minimal local anesthesia administration. Although there may be some mild discomfort during treatment to sensitive areas, the administration of sleek ATTIVA cannulas makes treatment possible without anesthesia.
How long is the ATTIVA Radiofrequency treatment?
The typical treatment for ATTIVA treatments lasts from 20 minutes in localized areas to no more than a couple of hours for treatment of larger areas such as the buttocks.
What is the recovery duration for ATTIVA radiofrequency treatments?
Treatment times can vary based on the treatment area, with full recovery lasting from a few hours to a few days. Since patients remain awake throughout the treatment, there is no grogginess.
When is the use of Attiva radiofrequency treatment contraindicated?
Contraindications for using Attiva treatment are skin infections, wounds, erosions and herpes, acne and pustules, patients with pacemakers, neoplasms, and metal implants. In addition, patients who are pregnant should avoid elective procedures.
What is the biological effect of radiofrequency on the skin?
ATTIVA radio waves are electromagnetic waves that, by passing under the middle layer of the skin, produce and generate a large amount of heat without damaging its surface. The most important biological effect within tissue is the denaturation of proteins that form collagen fibers. Collagen gives the skin firmness and elasticity and is responsible for a smooth, wrinkle-free surface. Over the years, collagen production declines, leading to the formation of wrinkles and sagging.
Why do we see immediate results after ATTIVA radiofrequency treatments?
ATTIVA radiofrequency causes an instantaneous contraction of loose collagen fibers inside the skin, by induced heat ranging from 42 to 50 degrees, with visible effects of skin tightening and regeneration.
What are the subacute and delayed effects of ATTIVA radiofrequency treatments?
Subacute cellular metabolism of the entire tissue is stimulated, improving microcirculation and oxygenation. Delayed effects are observed following biochemically heat induced stimulation of the fibroblasts to produce new collagen and elastin while the old collagen is remodeled and renewed. The effects of the treatment are visible freshness, elasticity, and skin rejuvenation.
Which skin regions are treated with ATTIVA radiofrequency treatments?
ATTIVA endodermal radio-frequency skin lifting is used to tighten all parts of the skin where signs of aging and sagging appear. We use it for
– tightening and lifting of the skin of all regions of the face, especially the lower part of the face, known as jowls
– rejuvenation and lifting of the upper and lower eyelids, under eye bags
– tightening and rejuvenation of the skin of the neck and below the chin
– correction of fine wrinkles in all regions
– reduction of buttock cellulite
– tightening of the sagging skin of the abdomen, thighs, upper arms, and other regions
How is Attiva radiofrequency applied to scars?
Attiva radiofrequency treatment with induced heat of about 60 degrees remodels the fibrous material in scars and stimulates microcirculation, resulting in improved appearance and scar reduction. This energy is used to treat scars in all skin parts and of different ages.
Can Attiva radiofrequency lifting be used for lipolysis?
By applying thermal energy of about 60 to 65 degrees, we can destroy fat cells localized in the abdomen, hips, chin, and other body parts. Lipolysis treatments must be delivered only by positioning of the treatment wand tip in deeper planes in order to avoid external skin temperatures reaching 42 degrees Celsius. Thermal energy causes lysis, which describes the breaking down of fat cells by releasing triglycerides into the intercellular space. At the same time, improving circulation enables their elimination through lymphatic pathways.
Why is general anesthesia not required during Attiva radiofrequency treatments?
There are several reasons why general anesthesia is not required with Attiva treatments. First, only mini poke holes are required to create imperceptible portals for the introduction of the treatment wands. Since internal temperatures are routinely maintained between 42 to 50 degrees, stimulation of sensory pain nerves is avoided by keeping probe temperatures below 65 degrees Celsius. Even when lipolysis is employed, temperatures are maintained at 60 to 65 degrees Celsius, below the pain fiber trigger. In certain settings, it may be necessary to add a tumescent solution when generous fat removal is indicated.
Can Attiva® S.I.H. treatments be combined with other procedures?
Certainly, Attiva treatment can be combined with ancillary procedures. Procedures to be combine with Attiva include:
PRP
Fillers
Growth Factors
Suspension threads
Lipofilling
Stem cells
Laser
Peeling
Can ATTIVA treatments performed following filler augmentation?
Filler, as well as absorbable threads, are procedures that, if done earlier, may be compromised by subdermal heat emitted by Attiva® S.I.H. Specifically, the heat emitted by Attiva may result in the premature dissolution of fillers. In contrast, filler application or lipofilling may be employed simultaneously immediately following the administration of S.I.H.
What is radiofrequency energy?
Radiofrequency energy is an electromagnetic wave, generated by an energy emission device with a special transducer, which propagates through the soft tissues. This energy can be applied externally to the skin or from underneath by means of a special transducer inserted through the skin. The therapeutic effect is created by the effect of heat produced by the passage of radiofrequency wave currents through tissue structures being treated in the body. The generated heat is controlled by the current intensity and resistance that electric charges face while propagating inside the cells and the extracellular matrix of the tissues. According to physics law, we can define electric resistance as the interaction of a conductor (in this case biological area of the body under treatment) to the flowing electric power which gets transferred to heat. Heat intensity and the depth reached range from 2 to 10 mm from the tip of the transducer using the quantity of transmitted energy and the conductivity of the treated area. The rise of temperature can vary from 10° to 25°C. The generated energy, or Joules of heating, is best determined by the following equation: J=I² x R x T
Where J = energy expressed in Joule, I = current expressed in ampere, R = resistance of the body expressed in ohms, T = time expressed in seconds. Areas rich in fluids and adipose tissue offer more resistance (impedance), thus the generated heat will be greater.
Biological effects of Radiofrequency energy
The most important biological effect of radiofrequency consists, at the histological level, of denaturation of the primary, secondary, and tertiary structures of collagen fiber proteins. Denaturing collagen fibers results in contraction, shortening, and enlargement of girth resulting in a reduction in skin and soft tissue elasticity thereby giving a rejuvenating and sheen to the treated areas. Secondly, the generated heat stimulates the fibroblast to restructure the degenerated proteins by producing new conditioned collagen (80%), neo-collagen (20%), and elastin, protein matrices integral to making skin tight and elastic. Besides the lifting effect mentioned above, an oxygenating effect is obtained thanks to the rise of cellular metabolism and direct vasodilation of vessels which results in improvement of microcirculation activity. Radiofrequency may lead to a rise in vascularization; the latter reduces possible deposits due to hydric retention by producing a drainage action. Fibroblast bio-stimulation, drainage action, and oxygenation are three phenomena positively affecting the prominence of local tissue, contributing to the slimming action of the treated areas.
ATTIVA Radiofrequency Treatment Protocol
Depending on your chosen treatment and your anxiety or sensitivity, we will anesthetize your area of treatment with a numbing solution. Since the ATTIVA cannulas are sleek, < 1mm, a single needle stick is all that is needed, which means a tincture of numbing solution is all that is needed. This area is first cooled with your topical freezer which means that you will not feel any discomfort! If deemed necessary, numbing solution may be employed to anesthetize the entire area being treated. The anesthetic solution is created with 1% lidocaine mixed with epinephrine as well as bicarbonate solution to expedite its numbing capacity. The numbing solution is delivered through the use of a small 22 spinal needle. The amount of anesthetic solution is directly proportional to the area being treated, to the treatment times, and always titrated to the patient’s sensitivity. The solution is kept at room temperature to make it more comfortable when exposed to your tissues.
Once numbing has been established, the treatment probes which are less than one mm in girth are easily introduced through a small needle hole created with an 18 gauge. The treatment probes are of varying lengths that include 5cm, 10cm, 15cm, and 20cm depending on the area of the region being treated. The introduction of the cannula needle must be done as follows: The needle penetrates the skin perpendicularly for about 0.5 cm, and then it is tilted by 90° to span the area of treatment in the soft tissue plane parallel to the skin. Once the distal point of the established track is reached, the energy inducer is turned on with the foot pedal. Within a few seconds, the treating temperature is reached (between 45 to 50 degrees Celsius), and treatment is initiated by pulling back the cannula needle very slowly, paying much attention to remaining as close as possible to the constant set temperature. The machine signals the continuation of the set temperature with an oscillation of 2°C, with a green light, which becomes blue if the oscillation exceeds of 2°C. While treatment is being rendered, the thermal camera provides continuous feedback, assessing the homogeneity of the delivered heat both at the tip of the probe internally as well as the external skin temperature. Subdermal-induced heat therapy is rendered as needed based on the region and desired effects as below
- Skin Laxity Program
The skin laxity program is intended to treat excessive skin laxity that is correlated with dermal thinning, observed following dramatic or quick weight loss. These patients present with dermal thinning that results in loose and thinning skin of the arms and inner thighs, stretch marks and wrinkling of the abdomen and back, or cellulite of the posterior thighs and buttocks. Treatment protocols are defined by region and thickness of skin being treated, selecting the number of tracks, as well as the number of passes planned. The cannula needle probe then delivers heat energy with slow back-and-forth movements always paying attention to keep the selected internal temperature within 2°C. Running time is always assessed by your medical provider based on the patient’s starting condition and desired endpoints. The chosen cannula needle probes should measure 10 cm to 20 cm in length to cover these larger treatment areas. The desired internal probe temperatures should range between 45 to 60 degrees Celsius depending on the depth of treatment and thickness of the skin.
Improvement in cellulite is a unique benefit of ATTIVA S.I.H. therapy. This therapy is predicated on the pathophysiology of cellulite formation that involves both localized tightened bands as well as increased skin laxity and redundancy. Release of localized tight retaining ligaments using a controlled and distally accessed releasing instrument such as Aveli followed by S.I.H. therapy to counter skin laxity can be used to effectively reduce the appearance of undesirable cellulite that forms along the lower buttock and posterior thighs.
- Skin Lifting Program
This program is used when an important skin redraping is desired to counter sagging of the face. All treatments are defined by the area being treated which determines track design and the number of passes. With this program, the movement of the cannula needle must be done exclusively in retraction, namely from the distal border towards the access port. Running time depends on tissue conditions and passes must be limited to 1 or 2 in number. Treatment of the neck, jowls, cheeks, and forehead are most popular. Needle cannula probe lengths can range between 5 to 15mm depending on the chosen area. The desired internal probe temperatures should range between 45 to 50 degrees Celsius depending on the depth of treatment and thickness of the skin.
- Fine Wrinkle program
The fine wrinkle program is intended for reducing both superficial fine wrinkles around the mouth and eyes. Once access holes are made, 2 or 3 depending on the area intended for treatment, introduce the cannula needle PERPENDICULARLY for about 0.3 cm in those ones more superficial, and 0.5 cm for deeper ones; then rotate of 90° until parallel with the cutaneous level and advance the cannula needle in the treatment area until the treatment area border is reached. Once the set temperature is reached, with slow movements pull back the cannula needle with linear movements ALWAYS from a distal to proximal direction. Running times depend on tissue conditions and the number of passes should be limited to a single pass to avoid skin injury. The aim is to reduce the prominence and depth of the wrinkle by keeping the depth to near the subdermal level. Running time is always assessed by the operator on the basis of the patient’s tissue conditions, keeping temperature within 2°C of oscillation ranging between 42 to 45 degrees Celsius. The thermal camera should be followed closely to avoid reaching the safe limit of external skin temperature of 42 degrees Celsius. You must assess the homogeneity of the heat reached with precision during treatments.
ATTIVA Radiofrequency Treatment Pricing
Please see the following list of pricing defined for the treatment of specified regions. Please inquire regarding package pricing which will be discounted based on the number of desired treatment regions.
Area | Price Range |
Upper brows and forehead | $2000 |
Upper Eyelids | $2000 |
Lower Eyelids | $2000 |
Cheeks | $2000 |
Jowls | $2000 |
Neck and Double Chin | $3000 |
Knees | $2500 |
Medial thighs | $3000 |
Under Arms | $3000 |
Armpits | $2000 |
Abdomen | $4000 |
Upper and Middle back | $4000 |
Lower back and flanks | $4000 |
Buttock and posterior thighs | $5000 |
Conclusion: Attiva Radiofrequency Treatment
In summary, Attiva radiofrequency treatment provides a minimally invasive procedure to effectively counter skin laxity that develops with aging and following the effects of gravity. Treatments are well tolerated and can be performed with you being awake throughout. Furthermore, recovery is often seamless with patients returning to routine activity and even work within just a few days.